[56] Positive switching overlap
In the case of positive
overlap, the left-hand piston does not open the passage from P to
A until the tank has been completely isolated by the other
piston. Pressure is immediately fed to the load device (cylinder
or hydraulic motor) with the result that this starts
abruptly.