The Most Frequently Occurring Problems
When attempting to perform
certain actions, you are prompted to insert the FluidSIM
CD.
FluidSIM cannot find certain installation directories on the hard disk. Probably not all of the software components were loaded at the time of installation. Either insert the CD or reinstall the missing software components.
Component cannot be moved
or deleted.
Make sure that you are in
the Edit Mode (); components can only be
moved or deleted in the Edit Mode.
Components cannot be
dragged onto the drawing area.
Make sure that you are in the Edit Mode.
Components cannot be moved
or deleted in the Edit Mode.
Make sure that you have selected a component and not a component connection.
A line cannot be drawn
between two connections.
Make sure to check the following points:
1. FluidSIM is in the Edit Mode.
2. No other connections are selected.
3. Both connections do not have a blind plug.
4. Both connections are of the same type.
The parameters of a
component cannot be changed.
Make sure that FluidSIM is
in the Edit Mode or that the simulation has been paused
().
The hard disk is running
non-stop and the simulation is going slowly.
There is not enough memory available. A workaround is to quit other running applications or to quit Microsoft Windows © and restart the computer.
Already drawn lines, which
are reported to be superimposed, cannot be found.
Press the Del key immediately after accepting the message; then draw a new line.
FluidSIM does not behave
normally.
Exit both FluidSIM and Microsoft Windows ©, and then restart Microsoft Windows © and FluidSIM.
You are getting negative
values for pressure.
Negative values for pressure mean that from a physical standpoint, the power supply unit is not providing the necessary output. Often, the reason is that there is a too high tensile load on a cylinder. In reality this situation can lead to different reactions, depending on apparent loads and the power supply unit involved. For this reason FluidSIM simply indicates a negative pressure value.
The pressure drop on a
pressure relief valve is higher than its preset targeted nominal
value.
There is really no mistake here: A pressure relief valve has a preset nominal pressure threshold, which is related to a certain pressure flow. If the flow should increase beyond this value, a larger pressure drop will occur, according to the resistance characteristics of the valve. The pressure relief valve is also not in the position to guarantee a certain pressure in all circumstances.
Components cannot be
marked.
Please ensure that the option Protect Text Componentsis not activated and that the edit mode for the applicable drawing layer is activated.
Certain editing functions
are not available in the context menu.
The context menu contains a practical subset of possible editing functions. Probably the operation that you would like to utilize applies only to one component at a time; if this is the case check to see that only one component is selected.
There is no pressure drop
in the circuit, although a T-connection is apparently
open.
T-connections are considered to be different from other connections: As an aid in drawing, they must not be provided with blind plugs because they are automatically closed if no line is connected.
The simulation time runs
irregularly, although the slow-motion factor has been set to 1:1,
and “Keep
real-time” has been
activated.
Both a complex circuit diagram and a slow computer could be reasons for the inability of FluidSIM to guarantee adherence to real-time.
At certain connections
arrows for the flow direction are not displayed. The option
Display Flow Direction has been activated.
The arrows only appear when a connection actual has a flow passing through it. This situation is not to be confused with a high pressure at a connection.
The animation is not
repeated, although the “Loop” option has been
activated.
The “Loop” option only applies to an animation that is not contained in part of a presentation.
FluidSIM is not behaving as
expected, and you have already exited Microsoft Windows © and
started FluidSIM new again many times.
Please uninstall FluidSIM and run a new installation.
Paste is not available from
the menu, although a Copy operation has already taken
place.
Only selected objects can be copied to the clipboard. If no objects are selected, only the picture will be copied to the clipboard.
No educational film will
start playing.
Video playback requires appropriate hardware and software. Furthermore, FluidSIM needs to access the movie files. To ensure this, the FluidSIM-CD-ROM needs to be present in the drive or the video files need to have been copied to the hard disk during the installation.
The student version of
FluidSIM is being loaded each time you start, although you have
purchased the full version.
The FluidSIM CD contains both the student version and the full version of FluidSIM. During the installation procedure you are asked whether the full version or the student version shall be installed.
The mouse cursor is not
switching as described, especially on top of
connections.
Make sure that the option Large Mouse Cursor has not been activated. The large mouse cursor is designed to be used with a projector; here the switching of the mouse cursor is undesirable.
DXF Export... is not
available from the menu.
Make sure that you are in the Edit Mode and that the window is not empty.
The text that was exported
using the DXF filter does not appear as it did in
FluidSIM.
The DXF format does not sufficiently support textual objects. I.e., CAD programs may not possess the ability to translate all fonts, font attributes, font colors, and special symbols.