[55] Negative switching overlap

FluidSIM 4 Hydraulics

Previous Next

[55 Negative switching overlap

In the case of negative overlap, flow from A to T is not quite closed when the inlet P is opened. This means that the pressure at port A rises slowly and the piston starts gently.

 

In manufacturers' data sheets, overlap positions are shown within dotted lines between the switching positions, or the overlap positions are shown in color or with a patterned background.