Automatic Switch Altering

FluidSIM 4 Hydraulics

Previous Next

Automatic Switch Altering

FluidSIM recognizes delay switches, limit switches, and pressure switches by the nature of their usage and by their labels and supplies the corresponding symbol for the switch in the electrical circuit:  for switch-on delayed,  for switch-off delayed,  for mechanical operated switches, and  for pressure operated switches. The representation of switches that are actuated by cylinders can be determined by selecting the corresponding switch type in the component's properties dialog:

 

This means that there do not exist special symbols for these switches in the FluidSIM component library. Instead the symbols for simple switches can be utilized:

 


Previous Next