[70] Sequence valve
The example shows a circuit
with a pressure relief valve used as a pressure sequence valve.
The pressure at the pilot piston of the PRV rises via the
pressure regulator. The PRV opens and the high-pressure pump
delivers directly to the tank. As soon as the 2/2-way valve
opens, the pressure drops. The pressure relief valve closes and
the high pressure pump is connected to the system.