niHSDIO Reset

NI Digital Waveform Generator/Analyzer

niHSDIO Reset

Resets the session to its Initial state. All channels and front panel terminals are put into a high-impedance state. All software attributes are reset to their initial values. During a reset, routes of signal between this and other devices are released, regardless of which device created the route. For instance, a trigger signal being exported to a PXI trigger line and used by another device will no longer be exported. Details

instrument handle identifies your instrument session. instrument handle was obtained from the niHSDIO Init Acquisition Session VI or the niHSDIO Init Generation Session VI.
error in describes error conditions that occur before this VI or function runs.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a negative error code. If status is FALSE, code is 0 or a warning code.
source identifies where an error occurred. The source string includes the name of the VI that produced the error, what inputs are in error, and how to eliminate the error.
instrument handle out passes a reference to your instrument session to the next VI. instrument handle was obtained from the niHSDIO Init Acquisition Session VI or the niHSDIO Init Generation Session VI.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source identifies where and why an error occurred. The source string includes the name of the VI that produced the error, what inputs are in error, and how to eliminate the error.

niHSDIO Reset Details

The niHSDIO Reset VI is applied to the entire device. If you have both a generation and an acquisition session active, the niHSDIO Reset VI resets the current session, including attributes, and invalidates the other session if it is committed or running. The other session must be closed.