Triggers:Script:Digital Level:Impedance

NI Digital Waveform Generator/Analyzer

Triggers:Script:Digital Level:Impedance

Short Name: ScriptTrig.DigLevel.Impedance

Specifies the impedance on the channel configured for the digital level Script trigger.

Refer to the following table for the supported settings for your device. NI-HSDIO returns an error if you select an unsupported setting.

Device Supported Value
NI 654x 100
NI 655x 50 or 10000
NI 656x 100 in LVDS terminal configuration
10000 in single-ended terminal configuration

This attribute is only set if the trigger is configured to use a PFI channel, and it is ignored if the trigger is configured for any other channel.

Units: ohms

Remarks

The following table lists the characteristics of this property.

Data Type ViReal64
Permissions R/W
Channel Based No
High-Level VI None