Dynamic Generation Timing Diagrams

NI Digital Waveform Generator/Analyzer

Dynamic Generation Timing Diagrams

The following figure illustrates the data and clock positions available when generating waveforms with the NI 654x. For simplicity, the data is shown delayed by 25% of the clock period; however, this value can vary between 0% and 100%.

Note  Data generation on the rising clock edge, falling clock edge, or delayed, is per channel selectable. However, in the delayed case, the delay value is constant across all delayed channels.

Dynamic Generation Timing Diagrams

For more information about using NI-HSDIO to adjust the data position, refer to Configuring Data Position.

Generation Provided Setup and Hold Times Timing Diagram

NI 654x Generation Provided Setup and Hold Times