Error Code: 0x14
The most common cause of this error code is that the Name specified in the System field during connect does not exist in the LANSA Routing table. Check that you have correctly entered the Name and check that the routing table entry exists. The host route is set up during the install. Refer to Connection Information to Master or Task: Define Data/Application Server Name in the .
Another common cause of this error code is that the LANSA Listener is not active. Check that the Listener is active as described in the Verify Listener is Active in the or Set Up Listener on the Data/Application Server in the .
You may also receive this error if:
- the port you are attempting to use is blocked or not open.
Check with your network administrator to determine if a firewall is blocking the port specified in your Host Routes Table.
That is, are you connecting to the LANSA Web Administrator from an outside network and going through a firewall if port 4545 (default) is not open?
- the incorrect communications method has been specified (that is, APPC instead of TCP/IP) so check the Server configuration. Sometimes this will generate an LCE0052 error, which usually also causes error WCPIC32.dll not found, i.e. it thinks you are trying to use APPC).
- communications method not set to SOCKET.