NI PXI-2584 Relay Replacement

NI Switches

NI PXI-2584 Relay Replacement

The NI PXI-2584 uses reed relays.

Refer to the following table for information about ordering replacement relays.

Relay Manufacturer Part
Coto Technology 9104-05-11

Complete the following sets of steps to disassemble your switch module, replace a failed relay, and reassemble your switch module.

Disassemble the Switch Module

  1. Ground yourself using a grounding strap or a ground connected to your PXI chassis.
    Note  Properly grounding yourself prevents damage to your switch module from electrostatic discharge.
  2. Remove the four screws that secure the plastic cover on the top and plastic lead cover on the bottom of the switch assembly.

    1 Screws
    2 Plastic Cover
    3 Plastic Lead Cover
  3. Carefully separate the adhered top cover absorber from the relays by slowly prying up on the cover. (Note: some metal relay caps might come loose during this process and can be put back onto the relays after you have completed relay replacement.)
  4. Locate the relay you want to replace. Refer to the following figure and table for relay locations.

    Channel
    Name
    Relay
    Name
    CH0 K0
    CH1 K1
    CH2 K2
    CH3 K3
    CH4 K4
    CH5 K5
    CH6 K6
    CH7 K7
    CH8 K8
    CH9 K9
    CH10 K10
    CH11 K11

Replace the Relay

Make sure you have the following:

  • Temperature-regulated soldering iron set to 300 °C
  • 60/40 Lead/Tin solder (flux core)
  • Solder wick
  • Isopropyl alcohol
  • Cotton swabs

Replace the relay as you would any other through-hole part. Trim the replaced relay leads to under 0.05 inch protrusion.

Reassemble the Switch Module


Replace the top cover while carefully aligning the standoffs with the mounting holes in the module. Secure the bottom cover using the four screws removed in Disassemble the Module, step 2.

Tip  In NI-SWITCH 3.1 or later, you can use the Switch Soft Front panel to reset the relay count after you have replaced a failed relay.