NI PXI-2584 Independent Topology
Use the independent topology to utilize the full routing capabilities of the NI PXI-2584. For example, when measuring stacked signals, use the independent topology to configure the NI PXI-2584 as an interleaved multiplexer.
The following figure represents the NI PXI-2584 in the independent topology.
Making a Connection
Both the scanning command, ch2->com0;, and the immediate operation, niSwitch Connect Channels VI or the niSwitch_Connect function with parameters ch2 and com0, result in the following connection:
signal connected to CH2 is routed to COM0
Pinout
The following figure identifies the pins for the NI PXI-2584 in the independent topology.