When using the NI PXI-2530 in the independent topology, connect your signals using the NI TB-2630 terminal block. Select this topology to utilize the full routing capabilities of the NI PXI-2530.

Note  When using the independent topology, always select NONE in MAX for the terminal block.

With the independent topology, you can control the individual relays using the niSwitch Relay Control VI or the niSwitch_RelayControl function, or you can use the niSwitch Connect Channels VI or the niSwitch_Connect function.

Signal Connections

Refer to the Signal Connections section for the NI PXI-2530 front connector pinout and NI TB-2630 terminal mapping.