NI PXI-2576 Independent Topology

NI Switches

NI PXI-2576 Independent Topology

When using the NI PXI-2576 in the independent topology, connect the signals using the NIĀ TB-2676 terminal block. Select this topology to utilize the full routing capabilities of the NI PXI-2576. The following figure represents the NI PXI-2576 in the independent topology.

Making a Connection

With the independent topology, you can control the individual relays using the niSwitch Relay Control VI or the niSwitch_RelayControl function, or you can use the niSwitch Connect Channels VI or the niSwitch_Connect function.

Pinout

The following figure and table identify the pins for the NI PXI-2576 in the independent topology.