NI PXI-2532 2-Wire 4×64 Matrix Topology

NI Switches

NI PXI-2532 2-Wire 4×64 Matrix Topology

The NI TB-2643 terminal block creates a 2-wire 4×64 matrix topology with the NI PXI-2532. The following figure represents the NI PXI-2532 in the 2-wire 4×64 matrix topology.

Making a Connection

Both the scanning command, r2->c1;, and the immediate operation, niSwitch Connect Channels VI or the niSwitch_Connect function with parameters r2 and c1, result in the following connections:

signal connected to R2+ is routed to C1+

signal connected to R2– is routed to C1–

Terminal Block Connections

The NI TB-2643 terminal block connects banks of the NI PXI-2532 to create the 2-wire 4×64 matrix topology. The following figure illustrates how the native banks of the NI PXI-2532 connect using the NI TB-2643 to create the 2-wire 4×64 matrix topology.

Bank Connection Diagram

The following tables list the pin assignments for the NI TB-2643 upper and lower column connection boards.

Upper Column Connection Board Column Pin Assignment

Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J3 Pin 1 C63– J3 Pin 9 C59– J3 Pin 17 C55– J3 Pin 25 C51–
J3 Pin 2 C63+ J3 Pin 10 C59+ J3 Pin 18 C55+ J3 Pin 26 C51+
J3 Pin 3 C62– J3 Pin 11 C58– J3 Pin 19 C54– J3 Pin 27 C50–
J3 Pin 4 C62+ J3 Pin 12 C58+ J3 Pin 20 C54+ J3 Pin 28 C50+
J3 Pin 5 C61– J3 Pin 13 C57– J3 Pin 21 C53– J3 Pin 29 C49–
J3 Pin 6 C61+ J3 Pin 14 C57+ J3 Pin 22 C53+ J3 Pin 30 C49+
J3 Pin 7 C60– J3 Pin 15 C56– J3 Pin 23 C52– J3 Pin 31 C48–
J3 Pin 8 C60+ J3 Pin 16 C56+ J3 Pin 24 C52+ J3 Pin 32 C48+

Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J2 Pin 1 C47– J2 Pin 9 C43– J2 Pin 17 C39– J2 Pin 25 C35–
J2 Pin 2 C47+ J2 Pin 10 C43+ J2 Pin 18 C39+ J2 Pin 26 C35+
J2 Pin 3 C46– J2 Pin 11 C42– J2 Pin 19 C38– J2 Pin 27 C34–
J2 Pin 4 C46+ J2 Pin 12 C42+ J2 Pin 20 C38+ J2 Pin 28 C34+
J2 Pin 5 C45– J2 Pin 13 C41– J2 Pin 21 C37– J2 Pin 29 C33–
J2 Pin 6 C45+ J2 Pin 14 C41+ J2 Pin 22 C37+ J2 Pin 30 C33+
J2 Pin 7 C44– J2 Pin 15 C40– J2 Pin 23 C36– J2 Pin 31 C32–
J2 Pin 8 C44+ J2 Pin 16 C40+ J2 Pin 24 C36+ J2 Pin 32 C32+

Lower Column Connection Board Column Pin Assignment

Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J3 Pin 1 C0+ J3 Pin 9 C4+ J3 Pin 17 C8+ J3 Pin 25 C12+
J3 Pin 2 C0– J3 Pin 10 C4– J3 Pin 18 C8– J3 Pin 26 C12–
J3 Pin 3 C1+ J3 Pin 11 C5+ J3 Pin 19 C9+ J3 Pin 27 C13+
J3 Pin 4 C1– J3 Pin 12 C5– J3 Pin 20 C9– J3 Pin 28 C13–
J3 Pin 5 C2+ J3 Pin 13 C6+ J3 Pin 21 C10+ J3 Pin 29 C14+
J3 Pin 6 C2– J3 Pin 14 C6– J3 Pin 22 C10– J3 Pin 30 C14–
J3 Pin 7 C3+ J3 Pin 15 C7+ J3 Pin 23 C11+ J3 Pin 31 C15+
J3 Pin 8 C3– J3 Pin 16 C7– J3 Pin 24 C11– J3 Pin 32 C15–


Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J3 Pin 1 C16+ J3 Pin 9 C20+ J3 Pin 17 C24+ J3 Pin 25 C28+
J3 Pin 2 C16– J3 Pin 10 C20– J3 Pin 18 C24– J3 Pin 26 C28–
J3 Pin 3 C17+ J3 Pin 11 C21+ J3 Pin 19 C25+ J3 Pin 27 C29+
J3 Pin 4 C17– J3 Pin 12 C21– J3 Pin 20 C25– J3 Pin 28 C29–
J3 Pin 5 C18+ J3 Pin 13 C22+ J3 Pin 21 C26+ J3 Pin 29 C30+
J3 Pin 6 C18– J3 Pin 14 C22– J3 Pin 22 C26– J3 Pin 30 C30–
J3 Pin 7 C19+ J3 Pin 15 C23+ J3 Pin 23 C27+ J3 Pin 31 C31+
J3 Pin 8 C19– J3 Pin 16 C23– J3 Pin 24 C27– J3 Pin 32 C31–

Row Pin Connections

The NI TB-2643 provides two ribbon cable headers for row connection. Use one cable header to connect to your application. Use the other cable header for column expansion.

The following table lists the pin assignments for row connection.

Pin Number Row
1 R0+
2 R0–
3 R1+
4 R1–
5 R2+
6 R2–
7 R3+
8 R3–
9–16

Row Protection Bypass Header

The row ribbon cable headers are isolated from the reed relays through 100 Ω resistors. To bypass these resistors, install a jumper in the appropriate position of J5 on the switch module interface board. The following table lists possible jumper locations.

Pin Connected Bypassed Row
1–2 R0+
3–4 R0–
5–6 R1+
7–8 R1–
9–10 R2+
11–12 R2–
13–14 R3+
15–16 R3–

Pinout

The following figure identifies the pins for the NI PXI-2532.

Caution  Low-voltage pins are reserved for future use. These pins should remain disconnected and isolated from row and column channels when high voltage is present.