NI PXI-2530 Relay Replacement
The NI PXI-2530 uses reed relays.
Refer to the following table for information about ordering replacement relays.
Relay Manufacturer | Part |
---|---|
Meder | MS05-1A71-75DHR |
Complete the following sets of steps to disassemble your switch module, replace a failed relay, and reassemble your switch module.
Disassemble the Switch Module
- Ground yourself using a grounding strap or a ground connected to your PXI chassis.
Note Properly grounding yourself prevents damage to your switch module from electrostatic discharge. - Remove the four screws that secure the top and bottom daughterboards to the switch assembly.
- Remove the insulator and the plastic spacers that separate the daughterboards.
1 Screws 2 Insulator 3 Plastic Spacers - To access the daughterboards, disconnect the PCB interconnect cable by lifting the PCB cable latch on the J1 connector.
1 PCB Interconnect Cable 2 PCB Cable Latch 3 J1 Connector - Carefully disconnect connectors J7 and J1 on the bottom daughterboard from connectors J8 and J1, respectively, on the top daughterboard.
1 J7 Connector 2 J1 Connector 3 Bottom Daughterboard 4 J8 Connector 5 J1 Connector 6 Top Daughterboard - Refer to the following figures to locate the relay you want to replace.
Top Daughterboard
Bottom Daughterboard
Replace the Relay
Make sure you have the following:
- Temperature-regulated soldering iron set to 300 °C
- 60/40 Lead/Tin solder (flux core)
- Solder wick
- Isopropyl alcohol
- Cotton swabs
Replace the relay as you would any other through-hole part.
Reassemble the Switch Module
Complete the Disassemble the Switch Module steps in reverse order to reassemble your switch module.
Tip In NI-SWITCH 3.1 or later, you can use the Switch Soft Front panel to reset the relay count after you have replaced a failed relay. |