NI PXI-2532 1-Wire Dual 4×64 Matrix Topology

NI Switches

NI PXI-2532 1-Wire Dual 4×64 Matrix Topology

The NI TB-2643 terminal block creates a 1-wire dual 4×64 matrix topology with the NI PXI-2532. The following figure represents the NI PXI-2532 in the 1-wire dual 4×64 matrix topology.

Making a Connection

For bank 0, both the scanning command, b0r2->b0c1;, and the immediate operation, niSwitch Connect Channels VI or the niSwitch_Connect function with parameters b0r2 and b0c1, result in the following connection:

signal connected to B0R2 is routed to B0C1

For bank 1, both the scanning command, b1r2->b1c1;, and the immediate operation, niSwitch Connect Channels VI or the niSwitch_Connect function with parameters b1r2 and b1c1, result in the following connection:

signal connected to B1R2 is routed to B1C1

Note  While you can, for example, connect B0R1 to B0C0, you cannot connect B0R1 directly to B1C1 in this topology.

Terminal Block Connections

The NI TB-2643 terminal block connects banks of the NI PXI-2532 to create the 1-wire dual 4×64 matrix topology. The following figure illustrates how the native banks of the NI PXI-2532 connect using the NI TB-2643 to create the 1-wire dual 4×64 matrix topology.

Bank Connection Diagram

The following tables list the pin assignments for the NI TB-2643 upper and lower column connection boards.

Upper Column Connection Board Column Pin Assignment

Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J3 Pin 1 B1C63 J3 Pin 9 B1C59 J3 Pin 17 B1C55 J3 Pin 25 B1C51
J3 Pin 2 B0C63 J3 Pin 10 B0C59 J3 Pin 18 B0C55 J3 Pin 26 B0C51
J3 Pin 3 B1C62 J3 Pin 11 B1C58 J3 Pin 19 B1C54 J3 Pin 27 B1C50
J3 Pin 4 B0C62 J3 Pin 12 B0C58 J3 Pin 20 B0C54 J3 Pin 28 B0C50
J3 Pin 5 B1C61 J3 Pin 13 B1C57 J3 Pin 21 B1C53 J3 Pin 29 B1C49
J3 Pin 6 B0C61 J3 Pin 14 B0C57 J3 Pin 22 B0C53 J3 Pin 30 B0C49
J3 Pin 7 B1C60 J3 Pin 15 B1C56 J3 Pin 23 B1C52 J3 Pin 31 B1C48
J3 Pin 8 B0C60 J3 Pin 16 B0C56 J3 Pin 24 B0C52 J3 Pin 32 B0C48

Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J2 Pin 1 B1C47 J2 Pin 9 B1C43 J2 Pin 17 B1C39 J2 Pin 25 B1C35
J2 Pin 2 B0C47 J2 Pin 10 B0C43 J2 Pin 18 B0C39 J2 Pin 26 B0C35
J2 Pin 3 B1C46 J2 Pin 11 B1C42 J2 Pin 19 B1C38 J2 Pin 27 B1C34
J2 Pin 4 B0C46 J2 Pin 12 B0C42 J2 Pin 20 B0C38 J2 Pin 28 B0C34
J2 Pin 5 B1C45 J2 Pin 13 B1C41 J2 Pin 21 B1C37 J2 Pin 29 B1C33
J2 Pin 6 B0C45 J2 Pin 14 B0C41 J2 Pin 22 B0C37 J2 Pin 30 B0C33
J2 Pin 7 B1C44 J2 Pin 15 B1C40 J2 Pin 23 B1C36 J2 Pin 31 B1C32
J2 Pin 8 B0C44 J2 Pin 16 B0C40 J2 Pin 24 B0C36 J2 Pin 32 B0C32

Lower Column Connection Board Column Pin Assignment

Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J3 Pin 1 B0C0 J3 Pin 9 B0C4 J3 Pin 17 B0C8 J3 Pin 25 B0C12
J3 Pin 2 B1C0 J3 Pin 10 B1C4 J3 Pin 18 B1C8 J3 Pin 26 B1C12
J3 Pin 3 B0C1 J3 Pin 11 B0C5 J3 Pin 19 B0C9 J3 Pin 27 B0C13
J3 Pin 4 B1C1 J3 Pin 12 B1C5 J3 Pin 20 B1C9 J3 Pin 28 B1C13
J3 Pin 5 B0C2 J3 Pin 13 B0C6 J3 Pin 21 B0C10 J3 Pin 29 B0C14
J3 Pin 6 B1C2 J3 Pin 14 B1C6 J3 Pin 22 B1C10 J3 Pin 30 B1C14
J3 Pin 7 B0C3 J3 Pin 15 B0C7 J3 Pin 23 B0C11 J3 Pin 31 B0C15
J3 Pin 8 B1C3 J3 Pin 16 B1C7 J3 Pin 24 B1C11 J3 Pin 32 B1C15


Pin Number Column Pin Number Column Pin Number Column Pin Number Column
J2 Pin 1 B0C16 J2 Pin 9 B0C20 J2 Pin 17 B0C24 J2 Pin 25 B0C28
J2 Pin 2 B1C16 J2 Pin 10 B1C20 J2 Pin 18 B1C24 J2 Pin 26 B1C28
J2 Pin 3 B0C17 J2 Pin 11 B0C21 J2 Pin 19 B0C25 J2 Pin 27 B0C29
J2 Pin 4 B1C17 J2 Pin 12 B1C21 J2 Pin 20 B1C25 J2 Pin 28 B1C29
J2 Pin 5 B0C18 J2 Pin 13 B0C22 J2 Pin 21 B0C26 J2 Pin 29 B0C30
J2 Pin 6 B1C18 J2 Pin 14 B1C22 J2 Pin 22 B1C26 J2 Pin 30 B1C30
J2 Pin 7 B0C19 J2 Pin 15 B0C23 J2 Pin 23 B0C27 J2 Pin 31 B0C31
J2 Pin 8 B1C19 J2 Pin 16 B1C23 J2 Pin 24 B1C27 J2 Pin 32 B1C31

Row Pin Connections

The NI TB-2643 provides two ribbon cable headers for row connection. Use one cable header to connect to your application. Use the other cable header for column expansion.

The following table lists the pin assignments for row connection.

Pin Number Row
1 B0R0
2 B1R0
3 B0R1
4 B1R1
5 B0R2
6 B1R2
7 B0R3
8 B1R3
9–16

Row Protection Bypass Header

The row ribbon cable headers are isolated from the reed relays through 100 Ω resistors. To bypass these resistors, install a jumper in the appropriate position of J5 on the switch module interface board. The following table lists possible jumper locations.

Pin Connected Bypassed Row
1–2 B0R0
3–4 B1R0
5–6 B0R1
7–8 B1R1
9–10 B0R2
11–12 B1R2
13–14 B0R3
15–16 B1R3

Pinout

The following figure identifies the pins for the NI PXI-2532.

Caution  Low-voltage pins are reserved for future use. These pins should remain disconnected and isolated from row and column channels when high voltage is present.