Expanding the NI PXI-2529 Matrix Using the NI TB-2634
The NI TB-2634 ships with three 2×16 ribbon cable connectors. You will need to supply and attach your own ribbon cables.
Getting Started
To expand the NI PXI-2529, you need the following items:
- Ribbon cable connectors
- Ribbon cable
- Two or more NI TB-2634 terminal blocks
- Two or more NI PXI-2529 switch modules
NI TB-2634 Terminal Reference
Refer to the following figure and complete either Expanding the NI PXI-2529 Columns or Expanding the NI PXI-2529 Rows to expand the NI PXI-2529.
Expanding the NI PXI-2529 Columns
Complete the following steps to expand the columns of an NI PXI-2529 using an NI TB-2634 terminal block.
- Connect one end of the ribbon cable to the row ribbon cable header on one NI TB-2634.
- Connect the ribbon cable to the row ribbon cable header on another NI TB-2634.
- (Optional) To expand the columns on the NI PXI-2529 further, attach another connector to the ribbon cable, and repeat the previous step.
The following figure illustrates the NI TB-2634 connections necessary to create a 2-wire 4×96 matrix.
Expanding the NI PXI-2529 Rows
Complete the following steps to expand the rows of an NI PXI-2529 using an NI TB-2634 terminal block.
- Connect one end of the ribbon cable to the first column ribbon cable header on one NI TB-2634.
- Connect the ribbon cable to the first column ribbon cable header on another NI TB-2634.
- (Optional) To expand the rows on the NI PXI-2529 further, attach another connector to the ribbon cable, and repeat the previous step.
- Repeat the previous steps to connect the second column ribbon cable headers on the NI TB-2634 terminal blocks.