NI PXI/PCI-5411/5431
Power-Up and Reset Conditions
When you power up the computer, the NI 5411/5431 is in the following state:
- The output is disabled and set to 0 V.
- The Sample clock is set to 40 MHz.
- The trigger mode is set to Continuous.
- The trigger source is set to automatic (the software provides the triggers).
- The digital filter is enabled.
- Digital pattern generation is disabled.
- Output attenuation remains unchanged from its previous setting.
- The analog filter remains unchanged from its previous setting.
- Output impedance remains unchanged from its previous setting.
When you reset the device using NI-FGEN or another application software, the NI 5411/5431 is in the same state as shown at power up with the following differences:
- Output attenuation is set to 0 dB.
- The analog filter is enabled.
- Output impedance is set to 50 Ω
- The PLL reference frequency is set to 20 MHz (NI 5411 only).
- The PLL reference source is set to internal tuning (NI 5411 only).
- The RTSI clock source is disabled (NI 5411 for PCI only).
- The SYNC duty cycle is set to 50%.