Molecular Devices Digidata 1550/1550A/1550B

WinWCP V5.3.8

Getting Started > Laboratory Interfaces > Molecular Devices Digidata 1550/1550A/1550B

 

Molecular Devices Corporation (www.moleculardevices.com)

 

The Molecular Devices Digidata 1550, 1550A and 1550B interfaces consists of self-contained, mains-powered digitiser units with BNC I/O sockets attached to the host computer via a USB 2.0 port. They support sampling rates up to 500 kHz (16 bit resolution) on up to 8 channels. They have a fixed input and output voltage range of +/-10V and support 8 analogue and 8 digital output channels.

Software Installation 

WinWCP uses Molecular Device's software libraries (AxDD1550.DLL, AxDD1550A.DLL or AxDD1550B.DLL) and device drivers for the Digidata 1550 and 1550A Series.

1)      Install the AxoScope (or PCLAMP ) software supplied with the Digidata 1550X.

2)      Reboot the computer.

3)      Attach the Digidata 1550 series interface unit to a USB port and turn it on.

4)      Run WinWCP and select from the main menu

Setup > Laboratory Interface

to open the Laboratory Interface Setup dialog box.

Then select Molecular Devices Digidata 1550 if you have a Digidata 1550, Molecular Devices Digidata 1550A or or Molecular Devices Digidata 1550B if you have a Digidata 1550B from the laboratory interface list.


 

Notes.

a) The HumSilencer feature of the Digidata 1550A and B is not currently supported by WinWCP.

b) When a recording is sweep manually terminated (by the user clicking the Stop button in the Record to Disk window) while WinWCP is waiting for an external START trigger pulse in the Ext Triggered recording mode or when the External Stimulus Trigger setting in a stimulus protocol is set to Y, an additional trigger pulse must be applied to the Digidata 1550 START input to terminate recording.

c) Support for analog input channel re-mapping (in the AI Ch. column of the Input Channels table in the Input Channels & Amplifier Setup dialog box) is limited. Recording channels can only be remapped to HIGHER analog input numbers.

Signal input / output connections

Signal input and output connections are made via the BNC sockets on the front of the Digidata 1550 series digitiser unit.

Digidata 1550 Series

Analog Input

I/O Panel

Notes

Ch. 0

Analog Input 0

 

Ch. 1

Analog Input 1

 

Ch. 2

Analog Input 2

 

Ch. 3

Analog Input 3

 

Ch. 4

Analog Input 4

 

Ch. 5

Analog Input 5

 

Ch. 6

Analog Input 6

 

Ch. 7

Analog Input 7

 

Analog Output

 

 

Ch. 0

Analog Out 0

 

Ch. 1

Analog Out 1

 

Ch. 2

Analog Out 2

 

Ch. 3

Analog Out 3

 

Trigger Inputs

 

 

Ext. Sweep Trigger

Start

 

Ext. Stimulus Trigger

Start

See Note 1

Digital Output

 

 

Ch. 0

Digital Output 0

 

Ch. 1

Digital Output 1

 

Ch. 2

Digital Output 2

 

Ch. 3

Digital Output 3

 

Ch. 4

Digital Output 4

 

Ch. 5

Digital Output 5

 

Ch. 6

Digital Output 6

 

Ch. 7

Digital Output 7

 


Note 1. An active-high TTL pulse on this input triggers the start of a stimulus program which has been set up with the External Stimulus Trigger = Y option.