Read Steps GeneratedReads the number of steps generated by a stepper output.
| Device Compatibility
|
Board ID is a unique number assigned by Measurement & Automation Explorer (MAX) used to send and receive commands and data to or from a specific NI motion controller. | |||||||
Axis or Stepper Output is the axis or stepper output to read. | |||||||
Ret Vect indicates the destination for the return data generated by this VI. Available return vectors include return data to the host (0xFF), return data to a variable (0x01 through 0x78), return data to an indirect variable (0x81 through 0xF8), and do not return data (0). Refer to Input and Return Vectors for more detailed information. | |||||||
error in (no error) describes error conditions that occur before this VI runs. The default input of this cluster is no error. If an error already occurred, this VI returns the value of error in in error out. The VI runs normally only if no incoming error exists. Otherwise, the VI passes the error in value to error out. The error in cluster contains the following parameters:
|
|||||||
Steps Generated is a value based on actual steps generated, as opposed to feedback position. | |||||||
Bd ID Out is provided for flow control. You can string together NI-Motion VIs by wiring the Bd ID Out terminal of one VI to the Board ID terminal of the next VI. | |||||||
Resource Output is the Axis, Vector Space, ADC, or Encoder you wired into the VI. Use Resource Output to pass the resource to another VI and/or to display information about the device. | |||||||
error out contains error information. If error in indicates an error, error out contains the same error information. Otherwise, it describes the error status that this VI produces.
|
Using This VI
The Read Steps Generated VI returns a number based on steps generated by a stepper axis or stepper output resource. For open-loop stepper axes, this VI returns exactly the same value as the Read Position VI.
For closed-loop stepper axes, this VI returns the actual number of steps generated while the Read Position VI returns the feedback position converted from counts to steps. The number of steps generated includes extra steps added during any pull-in move required to reach the target position.
To reset the value returned by this VI, use Reset Position. Reset Position sets the steps parameter to the reset position value.
Closed-Loop Stepper Example
Suppose you execute a move from position 0 to position 100, and 10 additional steps are generated for the pull-in move. Read Position returns 100, but Read Steps Generated returns 110. If you execute another move to position 50, Read Position returns 50, and Read Steps Generated returns 60.