Read DAC

NI-Motion VI

Read DAC

Reads the commanded DAC output value for an axis.

Details

Device Compatibility

DeviceCompatibility
7330
N
7340
Y
7344
Y
7350
Y
7390
N
NI SoftMotion Controller for CANopen—Accelnet
N
NI SoftMotion Controller for CANopen—Xenus
N
Board ID is a unique number assigned by Measurement & Automation Explorer (MAX) used to send and receive commands and data to or from a specific NI motion controller.
Axis or DAC is the axis or DAC to read.
Retn Vect indicates the destination for the return data generated by this VI. Available return vectors include return data to the host (0xFF), to a variable (0x01 through 0x78), to an indirect variable (0x81 through 0xF8), and do not return data (0). Refer to Input and Return Vectors for more detailed information.
error in (no error) describes error conditions that occur before this VI runs. The default input of this cluster is no error. If an error already occurred, this VI returns the value of error in in error out. The VI runs normally only if no incoming error exists. Otherwise, the VI passes the error in value to error out. The error in cluster contains the following parameters:
status is TRUE if an error occurred before this VI was called, or FALSE if not. If status is TRUE, code is a nonzero error code. If status is FALSE, code is zero or a warning code.
code is a number identifying an error or warning. If status is TRUE, code is a nonzero error code. If status is FALSE, code is zero or a warning code. Use the error handler VIs to look up the meaning of this code and display the corresponding error message.
source is a string that indicates the origin of the error, if any. Typically, source is the name of the VI in which the error occurred.
DAC Value is the 16-bit commanded DAC output value from the PID loop, where +32,767 corresponds to +10 V output and –32,768 corresponds to –10 V output.
Bd ID Out is provided for flow control. You can string together NI-Motion VIs by wiring the Bd ID Out terminal of one VI to the Board ID terminal of the next VI.
Resource Output is the Axis, Vector Space, ADC, or Encoder you wired into the VI. Use Resource Output to pass the resource to another VI and/or to display information about the device.
error out contains error information. If error in indicates an error, error out contains the same error information. Otherwise, it describes the error status that this VI produces.
status is TRUE if an error occurred, or FALSE if not. If status is TRUE, code is a nonzero error code. If status is FALSE, code is zero or a warning code.
code is a number identifying an error or warning. If status is TRUE, code is a nonzero error code. If status is FALSE, code is zero or a warning code. Use the error handler VIs to look up the meaning of this code and display the corresponding error message.
source is a string that indicates the origin of the error, if any. Typically, source is the name of the VI in which the error occurred.

Using This VI

The Read DAC VI returns the value of the specified DAC output. When sent to an axis, this VI returns the value of the primary DAC mapped to that axis. The signed 16-bit value returned corresponds to the ±10 V full scale range of the DAC.

This VI is used to monitor the output command from the PID loop. When the DAC output is connected to a torque block servo amplifier, you can use this value to calculate motor torque or to monitor the acceleration and deceleration portions of a trajectory to see how close the control loop is to saturating at its maximum torque limits.

When the DAC output is connected to a velocity block servo amplifier, the DAC value read is a direct representation of the instantaneous commanded velocity.