Read Memory Object DescriptionReads the ASCII text description for a program or buffer object.
| Device Compatibility
|
Board ID is a unique number assigned by Measurement & Automation Explorer (MAX) used to send and receive commands and data to or from a specific NI motion controller. | |||||||
Object (1) is a program or buffer stored in onboard RAM. | |||||||
error in (no error) describes error conditions that occur before this VI runs. The default input of this cluster is no error. If an error already occurred, this VI returns the value of error in in error out. The VI runs normally only if no incoming error exists. Otherwise, the VI passes the error in value to error out. The error in cluster contains the following parameters:
|
|||||||
Description is an ASCII character array of up to 32 characters that describes the object. | |||||||
Bd ID Out is provided for flow control. You can string together NI-Motion VIs by wiring the Bd ID Out terminal of one VI to the Board ID terminal of the next VI. | |||||||
Resource Out is the Axis, Vector Space, ADC, or Encoder you wired into the VI. Use Resource Output to pass the resource to another VI and/or to display information about the device. | |||||||
error out contains error information. If error in indicates an error, error out contains the same error information. Otherwise, it describes the error status that this VI produces.
|
Using This VI
The Read Memory Object Description VI returns the ASCII text description for a program or buffer object. The ASCII text description, previously loaded with the Load Memory Object Description VI, is useful as a quick reminder of the contents or purpose of an object stored in memory.