9 178 PUT_FIELD

LANSA Technical

9.178 PUT_FIELD

Þ Note: Built-In Function Rules.

Either inserts a new field into the LANSA Repository or updates details of an existing field.

Optionally this Built-In Function can present a prompt screen to the user that will allow details of a new or amended field to be further specified.

Argument values are exactly as the information presented in the Detailed Display of a Field Definition in the LANSA for i User Guide.

When a new field is being inserted into the dictionary, arguments that are not passed to the Built-In Function (or passed as null values) will adopt default values as described in Creating a New Field Definition in the LANSA for i User Guide.

When an existing field is being updated in the Repository, arguments that are not passed to the Built-In Function (or passed as null values) will remain unchanged by the update operation.

When zero is input as the 'Number of Decimals' parameter, it is treated as a null value. Use -1 in 'Number of Decimals' parameter to indicate a request to change the number of decimals of a field to zero.

If the copy validation checks option is used, all checks from the sequence number specified are deleted, then the validation checks are copied from the 'from field'. Any reference to the 'from field' in copied validation checks are replaced by the name of the field being inserted/updated.

Þ This is a Specialized Built-In Function for use in a Development Environment only.

For use with

LANSA for i

YES

Do not use on IBM i in an RDMLX partition.

Visual LANSA for Windows

YES

The prompting option is not supported in this environment.

The validation performed by this Built-In Function in the Windows environment is not as rigorous as that performed by the LANSA in the IBM i environment

Visual LANSA for Linux

NO

 

 

 

Arguments

No

Type

Req/ Opt

Description

Min Len

Max Len

Min Dec

Max Dec

1

A

Req

Prompt control details

Byte 1 - Prompt required

Y = prompt the user

N = do not prompt the user

Byte 2 - EXIT/SYSTEM key

Y = enable EXIT/SYSTEM key

N = do not enable EXIT/SYSTEM key

Byte 3 - MENU key

Y = enable MENU key

N = do not enable MENU key

1

3

 

 

2

A

Req

Name of field to be inserted or updated

1

10

 

 

3

A

Opt

Field type

A = alphanumeric

S = signed decimal numeric

P = packed decimal numeric

1

1

 

 

4

N

Opt

Length of field or total number of digits in field.

Note: For type A must be in range 1 - 256.

For type P or S must be in range 1 - 30.

3

15

0

0

5

N

Opt

Number of decimal positions Not applicable to type A field.

If updating an existing field, use -1 to make this argument 0.

1

15

0

0

6

A

Opt

Reference field name

If updating an existing field, use  '*NONE' to remove an existing reference field name.

1

10

 

 

7

A

Opt

Field description

1

40

 

 

8

A

Opt

Field label

1

15

 

 

9

A

Opt

Field column headings

List of 3 * A(20) headings

From - To   Description

1 - 20   Column Head 1
21 - 40   Column head 2
41 - 60   Column head 3

1

60

 

 

10

A

Opt

Output attributes list

List of 10 * A(4) attributes

1

40

 

 

11

A

Opt

Input attributes list

List of 10 * A(4) attributes

1

40

 

 

12

A

Opt

Edit code or edit word If first char is a quote (') then value is an edit word. Otherwise it is an edit code.

Not applicable to type A field

1

20

 

 

13

A

Opt

Default value of field

1

20

 

 

14

A

Opt

Optional alias name of field

1

30

 

 

15

A

Opt

System field flag

YES = a system field

NO = not a system field

3

3

 

 

16

A

Opt

Initial public access Ignored for update operations

1

7

 

 

17

A

Opt

Keyboard shift

1

1

 

 

18

A

Opt

Prompting Process/Function The first 10 bytes are PROCESS name, the next 7 are FUNCTION name.

1

17

 

 

19

A

Opt

(Re)Copy validation checks from Repository field

1

10

 

 

20

N

Opt

Starting sequence for copy

1

3

0

0

 

 

Return Values

No

Type

Req/ Opt

Description

Min Len

Max Len

Min Dec

Max Dec

1

A

Req

Return code

OK = field inserted/updated

EX = prompt was terminated by EXIT/SYSTEM function key

MU = prompt was terminated by MENU/CANCEL function key

ER = argument details are invalid or an authority problem has occurred. In case of "ER" return code error message(s) are issued automatically.

2

2