Ends an active edit session on a LANSA process definition

An edit session is commenced using the Built-In Function START_PROCESS_EDIT.

A process edit session should be terminated using the END_PROCESS_EDIT Built-In Function to ensure all locks/etc are released/shutdown in an orderly manner.

Any process edit session that receives a fatal error will have an END_PROCESS_EDIT command automatically issued.

Special Note: This Built-In Function provides access to very advanced facilities that basically allow RDML functions to construct new RDML functions.

This is a very specialized area that requires very good knowledge of the LANSA product. Use of this Built-In Function in a "commercial" application (e.g. Order Entry) is not normal and should not be attempted.

Þ This is a Specialized Built-In Function for use in a Development Environment only.

For use with

LANSA for i

YES

Do not use on IBM i in an RDMLX partition.

Visual LANSA for Windows

YES

 

Visual LANSA for Linux

NO

 

 

 

Arguments

No argument values.

Return Values

No

Type

Req/ Opt

Description

Min Len

Max Len

Min Dec

Max Dec

1

A

Req

Return code                 OK = edit session ended    ER = fatal error detected