Arbitrary Waveform Output:Onboard Signal Processing:Advanced:OSP Overflow Error Reporting
Short Name: OSP Overflow Error Reporting
Configures error reporting when the OSP block detects an overflow in any of its stages. Overflows lead to clipping of the waveform.
You can use the OSP Overflow Status property to query for overflow conditions whether or not the OSP Overflow Error Reporting property is enabled. The device will continue to generate after an overflow whether or not the OSP Overflow Error Reporting property is enabled.
Defined Values:
Error | NI-FGEN returns errors whenever an overflow has occurred in the onboard signal processing block. |
Disabled | NI-FGEN does not return errors when an overflow occurs in the onboard signal processing block. |
Remarks
The following table lists the characteristics of this property.
Data Type | ViInt32 |
Permissions | R/W |
Channel Based | No |
High-Level VI | None |