niFgen Configure Trigger (poly)
Configures the trigger source. The signal generator responds to a trigger according to the current trigger mode.
Note The signal generator must not be in the Generating state when you call this VI. |
Use the pull-down menu to select an instance of this VI.
niFgen Configure Digital Edge Start Trigger
Configures the Start trigger for edge triggering.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
Source specifies which trigger source the signal generator uses. | |||||||
edge specifies the edge to detect. You can choose Rising Edge or Falling Edge. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|
niFgen Configure Software Edge Start Trigger
Configures the Start trigger for software triggering. Use the niFgen Send Software Edge Triggering VI to assert the trigger condition.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|
niFgen Disable Start Trigger
Disables the Start trigger.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|
niFgen Configure Digital Edge Script Trigger
Configures a Script trigger for edge triggering.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
Source specifies which trigger source the signal generator uses. | |||||||
edge specifies the edge to detect. You can choose Rising Edge or Falling Edge. | |||||||
Trigger ID (Script Trigger 0) specifies the Script Trigger used for triggering. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|
niFgen Configure Digital Level Script Trigger
Configures a Script trigger for level triggering.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
Source specifies which trigger source the signal generator uses. | |||||||
Trigger When (High) specifies the active level for the desired trigger. | |||||||
Trigger ID (Script Trigger 0) specifies the Script Trigger used for triggering. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|
niFgen Configure Software Edge Script Trigger
Configures a Script trigger for software triggering. Use the niFgen Send Software Edge Triggering VI to assert the trigger condition.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
Trigger ID (Script Trigger 0) specifies the Script Trigger used for triggering. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|
niFgen Disable Script Trigger
Disables the Script trigger.
Instrument Handle identifies your instrument session. Instrument Handle was obtained from the niFgen Initialize VI or niFgen Initialize With Options VI. | |||||||
Trigger ID (Script Trigger 0) specifies the Script Trigger used for triggering. | |||||||
error in describes error conditions that occur before this VI or function runs.
| |||||||
Instrument Handle Out passes a reference to your instrument session to the next VI. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|