Power Requirement

+5 VDC (+/– 5%)

PXI-8461 (1 port) 800 mA typical
PXI-8461 (2 ports) 850 mA typical
PXI-8460 (1 port) 800 mA typical
PXI-8460 (2 ports) 850 mA typical
PXI-8464 (1 port) 850 mA typical
PXI-8464 (2 ports) 900 mA typical

Physical

Dimensions 16.0 cm by 10.0 cm (6.3 in. by 3.9 in.)
I/O connector 9-pin male D-SUB for each port

Operating Environment

Ambient temperature 0 to 55 °C
Relative humidity 10 to 90%, noncondensing

(Tested in accordance with IEC-60068-2-1, IEC-60068-2-2, IEC-60068-2-56.)

Storage Environment

Ambient temperature –20 to 70 °C
Relative humidity 5 to 95%, noncondensing

(Tested in accordance with IEC-60068-2-1, IEC-60068-2-2, IEC-60068-2-56.)

Functional Shock

30 g peak, half-sine, 11 ms pulse

(Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-T-28800E.)

Random Vibration

Operating 5 to 500 Hz, 0.3 grms
Nonoperating 5 to 500 Hz, 2.4 grms

(Tested in accordance with IEC-60068-2-64. Nonoperating test profile developed in accordance with MIL-T-28800E and MIL-STD-810E Method 514.)

Optical Isolation

Isolation up to 500 VDC (withstand, 2s max) channel-to-bus, port-to-port (two-port devices only)

PXI Trigger Bus

Trigger lines 7 input/output
PXI_STAR trigger1 input
Clock lines 1 input/output
PXI_Clk101 input
I/O compatibility TTL
Power-on state Input (High-Z)
Response Rising Edge Triggers

High-Speed CAN

Transceiver Philips TJA1041
Max baud rate 1 Mbps
Min baud rate 40 kbps
CAN_H, CAN_L bus lines –27 to +40 VDC
VBAT power requirement (jumper set to EXT) +8 to +27 VDC on V+ connector pin (referenced to V–)

Low-Speed/Fault-Tolerant CAN

Transceiver Philips TJA1054A
Max baud rate 125 kbps
Min baud rate 5 kbps,

10 kbps min for all error modes

CAN_H, CAN_L bus lines –27 to +40 VDC
VBAT power requirement (jumper set to EXT) +8 to +27 VDC on V+ connector pin (referenced to V–)

Single Wire CAN

Transceiver Philips AU5790
Max baud rate 33.3 kbps (normal transmission mode), 83.3 kbps (High-Speed transmission mode)
Min baud rate 5 kbps,

10 kbps min for all error modes

CAH_H bus line –10 to +18 VDC
VBAT power requirement (always required) +8 to +18 VDC (12 VDC typical) on V+ connector pin (referenced to V–)

XS Software Selectable

Relay service life

Mechanical 50,000,000 operations min. (at 36,000 operations per hour)

External mode digital I/O characteristics

MODE0, MODE1—digital outputs

STATUS—digital input

Level Min Max
VIL 0.0 V 0.8 V
VIH 2.0 V (typ) 5.0 V
VOL (IOL = 32 mA) 0.55 V
VOH (IOH = –32 mA) 3.8 V