PXI-846x Series 2 Specifications
Power Requirement
+5 VDC (+/– 5%)
PXI-8461 (1 port) | 800 mA typical |
PXI-8461 (2 ports) | 850 mA typical |
PXI-8460 (1 port) | 800 mA typical |
PXI-8460 (2 ports) | 850 mA typical |
PXI-8464 (1 port) | 850 mA typical |
PXI-8464 (2 ports) | 900 mA typical |
Physical
Dimensions | 16.0 cm by 10.0 cm (6.3 in. by 3.9 in.) |
I/O connector | 9-pin male D-SUB for each port |
Operating Environment
Ambient temperature | 0 to 55 °C |
Relative humidity | 10 to 90%, noncondensing |
(Tested in accordance with IEC-60068-2-1, IEC-60068-2-2, IEC-60068-2-56.)
Storage Environment
Ambient temperature | –20 to 70 °C |
Relative humidity | 5 to 95%, noncondensing |
(Tested in accordance with IEC-60068-2-1, IEC-60068-2-2, IEC-60068-2-56.)
Functional Shock
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-T-28800E.)
Random Vibration
Operating | 5 to 500 Hz, 0.3 grms |
Nonoperating | 5 to 500 Hz, 2.4 grms |
(Tested in accordance with IEC-60068-2-64. Nonoperating test profile developed in accordance with MIL-T-28800E and MIL-STD-810E Method 514.)
Optical Isolation
Isolation up to 500 VDC (withstand, 2s max) channel-to-bus, port-to-port (two-port devices only)
PXI Trigger Bus
Trigger lines | 7 input/output |
PXI_STAR trigger | 1 input |
Clock lines | 1 input/output |
PXI_Clk10 | 1 input |
I/O compatibility | TTL |
Power-on state | Input (High-Z) |
Response | Rising Edge Triggers |
High-Speed CAN
Transceiver | Philips TJA1041 |
Max baud rate | 1 Mbps |
Min baud rate | 40 kbps |
CAN_H, CAN_L bus lines | –27 to +40 VDC |
VBAT power requirement (jumper set to EXT) | +8 to +27 VDC on V+ connector pin (referenced to V–) |
Low-Speed/Fault-Tolerant CAN
Transceiver | Philips TJA1054A |
Max baud rate | 125 kbps |
Min baud rate | 5 kbps, 10 kbps min for all error modes |
CAN_H, CAN_L bus lines | –27 to +40 VDC |
VBAT power requirement (jumper set to EXT) | +8 to +27 VDC on V+ connector pin (referenced to V–) |
Single Wire CAN
Transceiver | Philips AU5790 |
Max baud rate | 33.3 kbps (normal transmission mode), 83.3 kbps (High-Speed transmission mode) |
Min baud rate | 5 kbps, 10 kbps min for all error modes |
CAH_H bus line | –10 to +18 VDC |
VBAT power requirement (always required) | +8 to +18 VDC (12 VDC typical) on V+ connector pin (referenced to V–) |
XS Software Selectable
Relay service life
Mechanical | 50,000,000 operations min. (at 36,000 operations per hour) |
External mode digital I/O characteristics
MODE0, MODE1—digital outputs
STATUS—digital input
Level | Min | Max |
---|---|---|
VIL | 0.0 V | 0.8 V |
VIH | 2.0 V (typ) | 5.0 V |
VOL (IOL = 32 mA) | — | 0.55 V |
VOH (IOH = –32 mA) | 3.8 V | — |