CD Set Delays to Model VI

Control Design VI and Function

CD Set Delays to Model VI

Owning Palette: Model Information VIs

Installed With: Control Design and Simulation Module

Sets the given delays in the system model. The data type you wire to the State-Space Model In input determines the polymorphic instance to use.

Use the pull-down menu to select an instance of this VI.

 Place on the block diagram  Find on the Functions palette

CD Set Delays to Model (State-Space)

State-Space Model In contains a mathematical representation of and information about the system for which this VI sets time delays.
Input Delays is an array of input delays where the ith element of this array is the time delay in the ith input of the system. If you do not wire an input to Input Delays, the VI uses the input delays from the State-Space Model In input.
Output Delays is an array of output delays where the ith element of this array is the time delay in the ith output of the system. If you do not wire an input to Output Delays, the VI uses the output delays from the State-Space Model In input.
Transport Delays is a 2D-array. The ijth element of this array is the time delay between the ith output and jth input pair of the system.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out is the modified form of the model with its delays set according to the values given in Input Delays, Output Delays, and Transport Delays. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Set Delays to Model (Transfer Function)

Transfer Function Model In contains a mathematical representation of and information about the system for which this VI sets time delays.
Input Delays is an array of input delays where the ith element of this array is the time delay in the ith input of the system. If you do not wire an input to Input Delays, the VI uses the input delays from the State-Space Model In input.
Output Delays is an array of output delays where the ith element of this array is the time delay in the ith output of the system. If you do not wire an input to Output Delays, the VI uses the output delays from the State-Space Model In input.
Transport Delays is a 2D-array. The ijth element of this array is the time delay between the ith output and jth input pair of the system.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out is the modified form of the model with its delays set according to the values given in Input Delays, Output Delays, and Transport Delays. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Set Delays to Model (Zero-Pole-Gain)

Zero-Pole-Gain Model In contains a mathematical representation of and information about the system for which this VI sets time delays.
Input Delays is an array of input delays where the ith element of this array is the time delay in the ith input of the system. If you do not wire an input to Input Delays, the VI uses the input delays from the State-Space Model In input.
Output Delays is an array of output delays where the ith element of this array is the time delay in the ith output of the system. If you do not wire an input to Output Delays, the VI uses the output delays from the State-Space Model In input.
Transport Delays is a 2D-array. The ijth element of this array is the time delay between the ith output and jth input pair of the system.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out is the modified form of the model with its delays set according to the values given in Input Delays, Output Delays, and Transport Delays. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.