CD Multiply Models VI

Control Design VI and Function

CD Multiply Models VI

Owning Palette: Model Interconnection VIs

Installed With: Control Design and Simulation Module

Multiplies two models by using matrix multiplication. If you are multiplying two models, the number of outputs of the Model 1 must be equal to the number of inputs of Model 2. The models either must be continuous-time models or must have the same sampling time if they are discrete-time models.

You also can multiply a multiple-input multiple-output (MIMO) model by a single-input single-output (SISO) model or by a constant Gain. This operation involves element multiplication instead of matrix multiplication.

The data types you wire to the Model 1 and Model 2 inputs determine the polymorphic instance to use.

This VI might convert one or both input models to different forms before connecting the models. Refer to the LabVIEW Control Design User Manual for more information about appending models.

Details  

Use the pull-down menu to select an instance of this VI.

 Place on the block diagram  Find on the Functions palette

CD Multiply Models (Transfer Function and Gain)

Model 1 specifies the first model this VI uses to create the Model Out.
Gain specifies the gain by which this VI multiplies the model.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Multiply Models (Zero-Pole-Gain and Gain)

Model 1 specifies the first model this VI uses to create the Model Out.
Gain specifies the gain by which this VI multiplies the model.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Multiply Models (State-Space and State-Space)

Model 1 specifies the first model this VI uses to create the Model Out.
Model 2 specifies the second model this VI uses to create the Model Out.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Multiply Models (Transfer Function and Transfer Function)

Model 1 specifies the first model this VI uses to create the Model Out.
Model 2 specifies the second model this VI uses to create the Model Out.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Multiply Models (Zero-Pole-Gain and Zero-Pole-Gain)

Model 1 specifies the first model this VI uses to create the Model Out.
Model 2 specifies the second model this VI uses to create the Model Out.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Multiply Models (State-Space and Gain)

Model 1 specifies the first model this VI uses to create the Model Out.
Gain specifies the gain by which this VI multiplies the model.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

CD Multiply Models Details

This VI supports delays. This VI transfers the delay information from the input models to the augmented model. Refer to the LabVIEW Control Design User Manual for more information about delays.