Owning Palette: Model Interconnection VIs
Installed With: Control Design and Simulation Module
Divides Model 1 by a constant Gain such that the Model Out represents the quotient of these inputs. This operation is equivalent to multiplying the Model 1 by the inverse of the Gain. Therefore, if this VI cannot calculate the inverse of the Gain, LabVIEW returns an error.
You also can divide two models by one another. In this situation, both models either must be continuous-time models or must have the same sampling time if they are discrete-time models.
The data types you wire to the Model 1 and Gain inputs determine the polymorphic instance to use.
This VI might convert one or both input models to different forms before connecting the models. Refer to the LabVIEW Control Design User Manual for more information about appending models.
Use the pull-down menu to select an instance of this VI.
Place on the block diagram | Find on the Functions palette |
CD Divide Models (State-Space by Gain)
Model 1 specifies the model that is the dividend. | |||||||
Gain specifies the gain that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Gain by State-Space)
Gain specifies the gain that is the dividend. | |||||||
Model 2 specifies the model that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Transfer Function by Gain)
Model 1 specifies the model that is the dividend. | |||||||
Gain specifies the gain that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Gain by Transfer Function)
Gain specifies the gain that is the dividend. | |||||||
Model 2 specifies the model that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Zero-Pole-Gain by Gain)
Model 1 specifies the model that is the dividend. | |||||||
Gain specifies the gain that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Gain by Zero-Pole-Gain)
Gain specifies the gain that is the dividend. | |||||||
Model 2 specifies the model that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (State-Space by State-Space)
Model 1 specifies the model that is the dividend. | |||||||
Model 2 specifies the model that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Transfer Function by Transfer Function)
Model 1 specifies the model that is the dividend. | |||||||
Model 2 specifies the model that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models (Zero-Pole-Gain by Zero-Pole-Gain)
Model 1 specifies the model that is the dividend. | |||||||
Model 2 specifies the model that is the divisor. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Model Out returns the model this VI produces. When the two input models are not of the same model type, the following model hierarchy determines the model type of the resulting model: state-space>transfer function>zero-pole-gain. For example, if one input is a state-space model and the other is a zero-pole-gain model, the resulting model is a state-space model. To access and modify the data in the model, use the Model Information VIs. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD Divide Models Details
This VI supports delays. This VI transfers the delay information from the input models to the augmented model. Refer to the LabVIEW Control Design User Manual for more information about delays.