CD State Feedback Controller VI
Owning Palette: Implementation VIs and Functions
Installed With: Control Design and Simulation Module
Implements a state-space controller where the Controller Action equals –Controller Gain * States.Use the pull-down menu to select an instance of this VI.
Place on the block diagram | Find on the Functions palette |
CD State Feedback Controller (Single Output)
States specifies the initial states of the controller. | |||||||
Controller Gain specifies the gains that premultiply the States to calculate the manipulated input to drive the system towards or back to a reference. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Controller Action returns the current value of the control action. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
CD State Feedback Controller (Multiple Outputs)
Initialize specifies whether to restart the calculation from any initial values you provide. The default is FALSE. | |||||||
States specifies the initial states of the controller. | |||||||
Controller Gain specifies the gains that premultiply the States to calculate the manipulated inputs to drive the system towards or back to a reference. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
Controller Action returns the current values of the control action. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|