Step Name Description
Read/Write I/O Reads and writes digital I/O lines on NI Smart Cameras and NI image acquisition devices.
Read/Write I/O (NI-IMAQ I/O) Reads and writes digital I/O lines and ports on NI CVS-1450 Series Compact Vision System or NI PCI-8254R/PCIe-8255R IEEE 1394 interface devices with reconfigurable I/O.
Read/Write I/O (NI-DAQmx I/O) Read and writes digital and analog I/O lines or ports on NI data acquisition (DAQ) devices.
Generate Pulse Generates a single pulse or a pulse train using the digital output lines on NI Smart Cameras and NI image acquisition devices.
Generate Pulse (NI-IMAQ I/O) Generates a single pulse or a pulse train using the digital output lines on NI CVS-1450 Series Compact Vision Systems, or NI PCI-8254R/PCIe-8255R IEEE 1394 interface devices with reconfigurable I/O.
Serial I/O Communicates with devices, such as a PLC or robot, through serial commands. You can export measurements and pass/fail results to external devices. You can also configure your system to wait for a signal from an external device to start your inspection.
TCP I/O Communicates with devices through TCP commands. You can export measurements and pass/fail results to external devices.
Modbus Slave Communicates with Modbus Master devices, such as touch screens and other Human Machine Interfaces (HMI) and terminals. Modbus is an application layer messaging protocol that provides client/server communication between devices connected on different types of buses or networks. Vision Builder AI supports both the serial and TCP/IP physical layers. Refer to Modbus Concepts for related information.