Counter Input:Period:Measurement Specifications:Method Property
Short Name: CI.Period.MeasMeth
Property of DAQmx Channel
Specifies the method to use to measure the period of the signal.
Low Frequency with 1 Counter (10105) | Use one counter that uses a constant timebase to measure the input signal. |
High Frequency with 2 Counters (10157) | Use two counters, one of which counts pulses of the signal to measure during the specified measurement time. |
Large Range with 2 Counters (10205) | Use one counter to divide the frequency of the input signal to create a lower-frequency signal that the second counter can more easily measure. |
Remarks
The following table lists the characteristics of this property.
Permissions | read/write |
Resettable | yes |
Settable while task is running | device-specific |
Available in Run-Time Engine | yes |