Analog Input:Strain:Strain Gage:Configuration Property
Short Name: AI.StrainGage.Cfg
Property of DAQmx Channel
Specifies the bridge configuration of the strain gages.
Full Bridge I (10183) | Four active gages with two pairs subjected to equal and opposite strains. |
Full Bridge II (10184) | Four active gages with two aligned with maximum principal strain and two Poisson gages in adjacent arms. |
Full Bridge III (10185) | Four active gages with two aligned with maximum principal strain and two Poisson gages in opposite arms. |
Half Bridge I (10188) | Two active gages with one aligned with maximum principal strain and one Poisson gage. |
Half Bridge II (10189) | Two active gages with equal and opposite strains. |
Quarter Bridge I (10271) | Single active gage. |
Quarter Bridge II (10272) | Single active gage and one dummy gage. |
Remarks
The following table lists the characteristics of this property.
Permissions | read/write |
Resettable | yes |
Settable while task is running | device-specific |
Available in Run-Time Engine | yes |