Read All Available Samples Property

NI-DAQmx Properties

Read All Available Samples Property

Short Name: ReadAllAvailSamp

Property of DAQmx Read

Specifies whether subsequent read operations read all samples currently available in the buffer or wait for the buffer to become full before reading. NI-DAQmx uses this setting for finite acquisitions and only when the number of samples to read is -1. For continuous acquisitions when the number of samples to read is -1, a read operation always reads all samples currently available in the buffer.

Remarks

The following table lists the characteristics of this property.

Permissionsread/write
Resettableyes
Settable while task is runningdevice-specific
Available in Run-Time Engineyes