Analog Input:General Properties:Signal Conditioning:Excitation:Advanced:Use Excitation For Scaling Property

NI-DAQmx Properties

Analog Input:General Properties:Signal Conditioning:Excitation:Advanced:Use Excitation For Scaling Property

Short Name: AI.Excit.UseForScaling

Property of DAQmx Channel

Specifies if NI-DAQmx divides the measurement by the excitation. You should typically set this property to TRUE for ratiometric transducers. If you set this property to TRUE, set AI.Max and AI.Min to reflect the scaling.

For example, if you expect to acquire a voltage between -5 and 5, and you use an excitation of .10 volts to scale the measurement, set AI.Min to -50 and set AI.Max to 50. If you set AI.Bridge.Cfg to No Bridge, this property has no effect on the measurement.

Remarks

The following table lists the characteristics of this property.

Permissionsread/write
Resettableyes
Settable while task is runningdevice-specific
Available in Run-Time Engineyes