More:AI Convert:Delay From Sample Clock:Delay Units Property

NI-DAQmx Properties

More:AI Convert:Delay From Sample Clock:Delay Units Property

Short Name: DelayFromSampClk.DelayUnits

Property of DAQmx Timing

Specifies the units of DelayFromSampClk.Delay.

NI-DAQmx uses the AI Convert Clock timebase to produce the delay.

If you set this property to Ticks and N is the value of DelayFromSampClk.Delay, N pulses of the AI Convert Clock Timebase occur after receiving a Sample Clock pulse before the acquisition of the sample begins.

If you set this property to Seconds, that number of seconds elapses after receiving a Sample Clock pulse before the acquisition of the sample begins.

Ticks (10304) Timebase ticks.
Seconds (10364) Seconds.

Remarks

The following table lists the characteristics of this property.

Permissionsread/write
Resettableyes
Settable while task is runningdevice-specific
Available in Run-Time Engineyes