More:AI Convert:Delay From Sample Clock:Delay Units Property
Short Name: DelayFromSampClk.DelayUnits
Property of DAQmx Timing
Specifies the units of DelayFromSampClk.Delay.
NI-DAQmx uses the AI Convert Clock timebase to produce the delay.
If you set this property to Ticks and N is the value of DelayFromSampClk.Delay, N pulses of the AI Convert Clock Timebase occur after receiving a Sample Clock pulse before the acquisition of the sample begins.
If you set this property to Seconds, that number of seconds elapses after receiving a Sample Clock pulse before the acquisition of the sample begins.
Ticks (10304) | Timebase ticks. |
Seconds (10364) | Seconds. |
Remarks
The following table lists the characteristics of this property.
Permissions | read/write |
Resettable | yes |
Settable while task is running | device-specific |
Available in Run-Time Engine | yes |