Short Name: MasterTimebase.Src

Property of DAQmx Timing

Specifies the terminal of the signal to use as the Master Timebase. On an E Series device, you can choose only between the onboard 20MHz Timebase or the RTSI7 terminal.

Remarks

The following table lists the characteristics of this property.

Permissionsread/write
Resettableyes
Settable while task is runningdevice-specific