viWrite
Purpose
Writes data to device or interface synchronously.
C Syntax
ViStatus viWrite(ViSession vi, ViBuf buf, ViUInt32 count, ViPUInt32 retCount)
Visual Basic Syntax
viWrite&(ByVal vi&, ByVal buf$, ByVal count&, retCount&)
Resource Classes
GPIB INSTR, GPIB INTFC, GPIB-VXI INSTR, Serial INSTR, TCPIP INSTR, TCPIP SOCKET, USB INSTR, USB RAW, VXI INSTR, VXI SERVANT
Parameters
Name | Direction | Description |
---|---|---|
vi |
IN |
Unique logical identifier to a session. |
buf |
IN |
Location of a data block to be sent to a device. |
count |
IN |
Number of bytes to be written. |
retCount |
OUT |
Number of bytes actually transferred. |
Return Values
Completion Codes | Description |
---|---|
VI_SUCCESS |
Transfer completed. |
Error Codes | Description |
---|---|
VI_ERROR_INV_OBJECT |
The given session reference is invalid. |
VI_ERROR_NSUP_OPER |
The given vi does not support this operation. |
VI_ERROR_RSRC_LOCKED |
Specified operation could not be performed because the resource identified by vi has been locked for this kind of access. |
VI_ERROR_TMO |
Timeout expired before operation completed. |
VI_ERROR_RAW_WR_PROT_VIOL |
Violation of raw write protocol occurred during transfer. |
VI_ERROR_RAW_RD_PROT_VIOL |
Violation of raw read protocol occurred during transfer. |
VI_ERROR_INP_PROT_VIOL |
Device reported an input protocol error during transfer. |
VI_ERROR_BERR |
Bus error occurred during transfer. |
VI_ERROR_INV_SETUP |
Unable to start write operation because setup is invalid (due to attributes being set to an inconsistent state). |
VI_ERROR_NCIC |
The interface associated with the given vi is not currently the controller in charge. |
VI_ERROR_NLISTENERS |
No-listeners condition is detected (both NRFD and NDAC are unasserted). |
VI_ERROR_IO |
An unknown I/O error occurred during transfer. |
VI_ERROR_CONN_LOST |
The I/O connection for the given session has been lost. |
Description
The viWrite() operation synchronously transfers data. The data to be written is in the buffer represented by buf. This operation returns only when the transfer terminates. Only one synchronous write operation can occur at any one time.