Sine Signal Function

Simulation VI and Function

Sine Signal Function

Owning Palette: Signal Generation Functions

Installed With: Control Design and Simulation Module

Generates the point-by-point value of a sine signal.

Details  Example

Dialog Box Options
Block Diagram Inputs
Block Diagram Outputs
 Place on the block diagram  Find on the Functions palette

Dialog Box Options

ParameterDescription
Polymorphic instanceSpecifies whether this function is Scalar or Vector. The default value is Scalar.
ParametersLists all the parameters associated with this function. Select a parameter from this list to configure the parameter. When you select a parameter, the parameter and its associated Parameter source control appear in the Parameter Information section of the configuration dialog box.
PreviewDisplays a graphical preview, if available, of the function output or configuration.
Parameter InformationContains the parameters you can configure for this function. You must select a parameter from the Parameters list to make that parameter and its associated Parameter source control visible in the Parameter Information section of the configuration dialog box.
Parameter sourceSpecifies whether you configure this parameter using the Configuration Dialog Box or a Terminal on the simulation diagram. The default value is Configuration Dialog Box. If you select Terminal, LabVIEW displays an input for that parameter on the simulation diagram, and you can wire values to that input to configure this function programmatically. If you select Configuration Dialog Box, LabVIEW removes that input from the simulation diagram. You then must set the value for this parameter inside the configuration dialog box.
amplitudeSpecifies the maximum amplitude of the sine signal. The default value is 1.
offsetSpecifies the amount by which to offset the y-values of the signal.
frequencySpecifies the frequency, in hertz, of the sine signal. The default value is 0.5.
phaseSpecifies the phase, in degrees, of the sine signal. The default value is 0.

Block Diagram Inputs

ParameterDescription
amplitudeSpecifies the maximum amplitude of the sine signal. The default value is 1.
offsetSpecifies the amount by which to offset the y-values of the signal.
frequencySpecifies the frequency, in hertz, of the sine signal. The default value is 0.5.
phaseSpecifies the phase, in degrees, of the sine signal. The default value is 0.

Block Diagram Outputs

ParameterDescription
outputReturns the value of the signal evaluated at the current simulation time. The default value is 1.

Sine Signal Details

The following equation defines the sine signal.

whereA is the amplitude
f is the frequency
t is the current simulation time
p is the phase
y is the output

The current value of the signal depends on the current simulation time.

Feedthrough Behavior

All input/output pairs of this function have direct feedthrough behavior.

Example

Refer to the SimEx Sine VI in the labview\examples\Control and Simulation\Simulation\Signal Generation directory for an example of using the Sine Signal VI.

 Open example  Browse related examples