DFD Build MRate Filter VI

Digital Filter Design VIs and Functions

DFD Build MRate Filter VI

Owning Palette: Multirate Utilities VIs

Installed With: Digital Filter Design Toolkit

Creates a multirate filter. You must manually select the polymorphic instance you want to use.

Example

Use the pull-down menu to select an instance of this VI.

 Place on the block diagram  Find on the Functions palette

DFD Build MRate Filter from TF

h(n) specifies the input transfer function this VI uses to create the filter.
factor specifies the sampling frequency conversion factor this VI uses to create the filter.
filtering mode specifies the processing mode of the filter that this VI creates.

0No Rate Change—Does not change the sampling frequency of a signal.
1Interpolation—Increases the sampling frequency of a signal to a higher sampling frequency that differs from the original frequency by an integer value. Interpolation also is known as up-sampling.
2Decimation (default)—Reduces the sampling frequency of a signal to a lower sampling frequency that differs from the original frequency by an integer value. Decimation also is known as down-sampling.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
multirate filter out returns a new multirate filter.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

DFD Build MRate Filter from FIR Filter

filter in specifies the input finite impulse response (FIR) filter that this VI uses to create the multirate filter.
factor specifies the sampling frequency conversion factor this VI uses to create the filter.
filtering mode specifies the processing mode of the filter that this VI creates.

0No Rate Change—Does not change the sampling frequency of a signal.
1Interpolation—Increases the sampling frequency of a signal to a higher sampling frequency that differs from the original frequency by an integer value. Interpolation also is known as up-sampling.
2Decimation (default)—Reduces the sampling frequency of a signal to a lower sampling frequency that differs from the original frequency by an integer value. Decimation also is known as down-sampling.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
multirate filter out returns a new multirate filter.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

DFD Build MRate Filter from MRate Filter

multirate filter in specifies the input multirate filter that includes the transfer function this VI uses to create the new multirate filter.
factor specifies the sampling frequency conversion factor this VI uses to create the filter.
filtering mode specifies the processing mode of the filter that this VI creates.

0No Rate Change—Does not change the sampling frequency of a signal.
1Interpolation—Increases the sampling frequency of a signal to a higher sampling frequency that differs from the original frequency by an integer value. Interpolation also is known as up-sampling.
2Decimation (default)—Reduces the sampling frequency of a signal to a lower sampling frequency that differs from the original frequency by an integer value. Decimation also is known as down-sampling.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
multirate filter out returns a new multirate filter.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

DFD Build MRate Filter from TF (Rational)

h(n) specifies the input transfer function this VI uses to create the filter.
factor contains the sampling frequency conversion factor of the multirate filter.
L contains the numerator factor of the rational resampling frequency conversion factor. The value of L must be an integer greater than zero. The value of L must not equal the value of M. The default is 8.
M contains the denominator factor of the rational resampling frequency conversion factor. The value of M must be an integer greater than zero. The value of M must not equal the value of L. The default is 3.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
multirate filter out returns a new multirate filter.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

DFD Build MRate Filter from FIR Filter (Rational)

filter in specifies the input finite impulse response (FIR) filter that this VI uses to create the multirate filter.
factor contains the sampling frequency conversion factor of the multirate filter.
L contains the numerator factor of the rational resampling frequency conversion factor. The value of L must be an integer greater than zero. The value of L must not equal the value of M. The default is 8.
M contains the denominator factor of the rational resampling frequency conversion factor. The value of M must be an integer greater than zero. The value of M must not equal the value of L. The default is 3.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
multirate filter out returns a new multirate filter.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

DFD Build MRate Filter from MRate Filter (Rational)

multirate filter in specifies the input multirate filter that includes the transfer function this VI uses to create the new multirate filter.
factor contains the sampling frequency conversion factor of the multirate filter.
L contains the numerator factor of the rational resampling frequency conversion factor. The value of L must be an integer greater than zero. The value of L must not equal the value of M. The default is 8.
M contains the denominator factor of the rational resampling frequency conversion factor. The value of M must be an integer greater than zero. The value of M must not equal the value of L. The default is 3.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
multirate filter out returns a new multirate filter.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

Example

Refer to the Create Multirate Filter VI in the labview\examples\Digital Filter Design\Getting Started\Design Filters directory for an example of using the DFD Build MRate Filter VI.

 Open example  Browse related examples