NI 9203 (FPGA Interface)

CompactRIO

NI 9203 (FPGA Interface)

CompactRIO 8-Channel, ±20 mA, 16-Bit Analog Input Module

FPGA I/O Node

You can use an FPGA I/O Node, configured for reading, with this device.

Terminals in Software

Use the FPGA I/O Node to access the following terminals for this device.

Terminal Description
AIx Analog input channel x, where x is the number of the channel. The NI 9203 has AI channels 0 to 7.

Arbitration

This device supports only the Arbitrate if Multiple Requestors Only option for arbitration. You cannot configure arbitration settings for this device.

Module Methods

Use the FPGA I/O Method Node to access the following method for this device. This device does not support any I/O methods.

Method Description
Set Input Range Sets the input range for a channel as either 0–20 mA or ±20 mA. This method overwrites the value you configure in the C Series Module Properties dialog box.

I/O Properties

Use the FPGA I/O Property Node to access the following properties for this device.

Property Description
LSB Weight (±20 mA range) Returns the LSB weight in pA/LSB for the channel. Use this value to convert and calibrate NI 9203 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box, and you set the input range to ±20 mA.
LSB Weight (4–20 mA range) Returns the LSB weight in pA/LSB for the channel. Use this value to convert and calibrate NI 9203 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box, and you set the input range to 0–20 mA.

Module Properties

Use the FPGA I/O Property Node to access the following properties for this device.

Property Description
Module ID Returns the module ID.
Offset (±20 mA range) Returns the calibration offset in pA for the channel. Use this value to convert and calibrate NI 9203 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box, and you set the input range to ±20 mA.
Offset (4–20 mA range) Returns the calibration offset in pA for the channel. Use this value to convert and calibrate NI 9203 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box, and you set the input range to 0–20 mA.
Serial Number Returns the unique serial number of the module.
Vendor ID Returns the National Instruments vendor ID, 0x1093.

Single-Cycle Timed Loop

This device does not support the single-cycle Timed Loop.

Hardware Documentation

Refer to the NI 9203 Operating Instructions and Specifications to learn about module specifications and how to use the module. Refer to the CompactRIO Related Documentation for further information about CompactRIO documentation.