Configuring the Master Timebase Source for the NI 9225/9229/9239 (FPGA Interface)
By default, the NI 9225/9229/9239 module uses the internal 12.8 MHz Onboard Clock as the master timebase source. In a system with multiple NI 9225/9229/923x modules, you can configure one of the NI 9225/9229/923x modules as the master timebase source (master) and configure the other NI 9225/9229/923x modules to use that master timebase source (slaves). Sharing the same master timebase source enables you to synchronize multiple NI 9225/9229/923x modules. The NI 9225/9229/9239 divides the master timebase source to acquire data at the data rate you configure.
Note The cRIO-9151 R Series Expansion chassis does not support synchronizing multiple NI 9225/9229/923x modules. |
Configuring the Onboard Clock as the Master Timebase Source
Complete the following steps to configure the internal 12.8 MHz Onboard Clock as the master timebase source.
- Configure the CompactRIO system, and add an NI 9225/9229/9239.
- Right-click the NI 9225/9229/9239 in the Project Explorer window and select Properties to display the C Series Module Properties dialog box.
- Select <Onboard Clock> from the Master Timebase Source pull-down menu.
- Click the OK button.
- Select File»Save All in the Project Explorer window.
Configuring a Master Module to Share the Master Timebase Source with Slaves
Complete the following steps to configure the master timebase source for a master module and slaves.
- Configure the CompactRIO system, and add an NI 9225/9229/9239.
- Right-click the NI 9225/9229/9239 in the Project Explorer window and select Properties to display the C Series Module Properties dialog box.
- Select <Onboard Clock> from the Master Timebase Source pull-down menu.
- Place a checkmark in the Export Onboard Clock checkbox.
- Right-click the NI 9225/9229/9239 you want to configure as a slave in the Project Explorer window and select Properties to display the C Series Module Properties dialog box.
- Select the name of the master module from the Master Timebase Source pull-down menu.
- Repeat steps 5 and 6 for each slave module you want to configure.
- Click the OK button.
- Select File»Save All in the Project Explorer window.