IviRFSigGen AM Scaling [AM]

LabVIEW IVI Class Driver

IviRFSigGen AM Scaling [AM]

IviRFSigGenModulateAM Property

Data
type
Access Applies to Coercion High Level VIs
R/W N/A None IviRFSigGen Configure AM [AM]

Description

Specifies linear or logarithmic attenuation for amplitude modulation. The unit of the IviRFSigGen>>Analog Modulation>>AM>>AM Depth [AM] property is changed with this setting.

Property Node Path

IviRFSigGen»Analog Modulation>>AM>>AM Scaling [AM]

Defined Values

IVIRFSIGGEN_VAL_AM_SCALING_LINEAR

IVIRFSIGGEN_VAL_AM_SCALING_LOGARITHMIC