IviPwrMeter Units

LabVIEW IVI Class Driver

IviPwrMeter Units

IviPwrMeterBase Property

Data
type
Access Applies to Coercion High Level VIs
R/W N/A None IviPwrMeter Configure Units

Description

Specifies the unit to which the RF power is converted after measurement.
The actual RF power of the signal on a channel is always measured in Watts. The value of this property is used to determine the units in which the IviPwrMeter>>Manual Range>>Range Upper [RNG] and IviPwrMeter>>Manual Range>>Range Lower [RNG] properties are specified. The unit of the measurement result returned by the Read and Fetch VIs also depends on the value of this property.

Property Node Path

IviPwrMeter»Basic Operation>>Units

Defined Values

IVIPWRMETER_VAL_DBM

IVIPWRMETER_VAL_DBMV

IVIPWRMETER_VAL_DBUV

IVIPWRMETER_VAL_WATTS