IviPwrMeter Error and Warning Codes
The functions in this class driver generate return values that report the status of this operation. To obtain a text description of the status code, or if the status code is not listed below, call the IviPwrMeter_error_message function. To obtain additional information about the error condition, use the IviPwrMeter_GetError and IviPwrMeter_ClearError functions.
|
Note If a function succeeds, it returns VI_SUCCESS which has a numeric value of 0. |
Status Code Ranges
Status Code Type |
Numeric Range (in Hex) |
Include File |
IviPwrMeter Errors |
0xBFFA2001 to 0xBFFA3FFF |
IviPwrMeter.h |
IviPwrMeter Warnings |
0x3FFA2001 to 0x3FFA3FFF |
IviPwrMeter.h |
Specific Driver Errors |
0xBFFA4000 to 0xBFFA5FFF |
Prefix.h |
Specific Driver Warnings |
0x3FFA4000 to 0x3FFA5FFF |
Prefix.h |
IVI Errors |
0xBFFA0000 to 0xBFFA1FFF |
ivi.h |
IVI Warnings |
0x3FFA0000 to 0x3FFA1FFF |
ivi.h |
Common Instrument Driver Errors |
0xBFFC0000 to 0xBFFCFFFF |
vpptype.h |
Common Instrument Driver Warnings |
0x3FFC0000 to 0x3FFCFFFF |
vpptype.h |
VISA Errors |
0xBFFF0000 to 0xBFFFFFFF |
visa.h |
VISA Warnings |
0x3FFF0000 to 0x3FFFFFFF |
visa.h |
The IviPwrMeter class driver defines the error codes shown in the following table in addition to the IVI defined error codes.
IviPwrMeter Warning Code
Warning Code |
Value |
Description |
IVIPWRMETER_WARN_UNDER_RANGE |
0x3FFA2001 |
Under Range warning |
IVIPWRMETER_WARN_OVER_RANGE |
0x3FFA2002 |
Over Range warning |
IviPwrMeter Error Codes
Error Codes |
Value |
Description |
IVIPWRMETER_ERROR_CHANNEL_NOT_ENABLED |
0xBFFA2001 |
Maximum time exceeded before the operation completed. |
IVIPWRMETER_ERROR_MAX_TIME_EXCEEDED |
0xBFFA2020 |
Maximum time exceeded before the operation completed. |
IVIPWRMETER_ERROR_TRIGGER_NOT_SOFTWARE |
0xBFFA1001 |
The trigger source is not software trigger. |
Related Topic