ViStatus IviPwrMeter_ConfigureTriggerSource (ViSession vi, ViInt32 triggerSource);

Purpose

This function configures the trigger source of the power meter.

Parameters

Name Type Description
vi ViSession The ViSession handle that you obtain from the IviPwrMeter_init or IviPwrMeter_InitWithOptions function. The handle identifies a particular instrument session.

Default Value: None

triggerSource ViInt32 Specifies the trigger source. After you call either the IviPwrMeter_Read or the IviPwrMeter_Initiate function, the Power Meter waits for the trigger you specify. The driver sets the IVIPWRMETER_ATTR_TRIGGER_SOURCE attribute to this value.

Defined Values:

IVIPWRMETER_VAL_IMMEDIATE (Immediate) - The power meter
exits the Wait-For-Trigger state immediately after
entering. It does not wait for a trigger of any kind.

IVIPWRMETER_VAL_EXTERNAL (External) - The power meter
exits the Wait-For-Trigger state when an internal
trigger event occurs on the measurement signal.

IVIPWRMETER_VAL_INTERNAL (Internal) - The power meter
exits the Wait-For-Trigger state when a trigger
occurs on the external trigger input.

IVIPWRMETER_VAL_SOFTWARE_TRIG (Software) - The power
meter exits the Wait-For-Trigger state when it
receives software trigger.

IVIPWRMETER_VAL_TTL0 (TTL0) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL0.

IVIPWRMETER_VAL_TTL1 (TTL1) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL1.

IVIPWRMETER_VAL_TTL2 (TTL2) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL2.

IVIPWRMETER_VAL_TTL3 (TTL3) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL3.

IVIPWRMETER_VAL_TTL4 (TTL4) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL4.

IVIPWRMETER_VAL_TTL5 (TTL5) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL5.

IVIPWRMETER_VAL_TTL6 (TTL6) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL6.

IVIPWRMETER_VAL_TTL7 (TTL7) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on TTL7.

IVIPWRMETER_VAL_ECL0 (ECL0) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on ECL0.

IVIPWRMETER_VAL_ECL1 (ECL1) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on ECL1.

IVIPWRMETER_VAL_PXI_STAR (PXI Star) - The power meter
exits the Wait-For-Trigger state when it receives
a trigger on PXI Star trigger bus.

IVIPWRMETER_VAL_RTSI_0 (RTSI0) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI0 line.

IVIPWRMETER_VAL_RTSI_1 (RTSI1) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI1 line.

IVIPWRMETER_VAL_RTSI_2 (RTSI2) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI2 line.

IVIPWRMETER_VAL_RTSI_3 (RTSI3) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI3 line.

IVIPWRMETER_VAL_RTSI_4 (RTSI4) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI4 line.

IVIPWRMETER_VAL_RTSI_5 (RTSI5) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI5 line.

IVIPWRMETER_VAL_RTSI_6 (RTSI6) - The power meter exits
the Wait-For-Trigger state when it receives a
trigger on RTSI6 line.

Default Value:
IVIPWRMETER_VAL_IMMEDIATE (Immediate)

Return Values