IVIDCPWR_ATTR_TRIGGER_SOURCE
IviDCPwrTrigger Attribute
Data Type | Access | Applies to | Coercion | High Level Functions | ID Definition |
---|---|---|---|---|---|
ViInt32 | R/W | Channel | N/A | IviDCPwr_ConfigureTriggerSource | 1250101 |
Description
Specifies the trigger source. After you call IviDCPwr_Initiate, the power supply waits for a trigger event from the source you specify with this attribute. After a trigger event occurs, the power supply changes the voltage level to the value of the IVIDCPWR_ATTR_TRIGGERED_VOLTAGE_LEVEL and the current limit to the value of the IVIDCPWR_ATTR_TRIGGERED_CURRENT_LIMIT attribute.