ENEB Error code
ENEB occurs when no GPIB interface exists at the I/O address specified in the configuration program. This occurs when the board is not physically plugged into the system, the I/O address specified during configuration does not match the actual board setting, or there is a system conflict with the base I/O address.
Solutions
Make sure there is a GPIB interface in your computer that is properly configured both in hardware and software using a valid base I/O address by running the NI-488.2 Troubleshooting Utility.
To start the NI-488.2 Troubleshooting Utility within Measurement & Automation Explorer, select Help»Troubleshooting»NI-488.2 Troubleshooting Utility or click on the following button.
Return to list of error codes |