SI Data Samples VI
Owning Palette: Utilities VIs
Installed With: System Identification Toolkit
Produces sample stimulus and response signals. You must manually select the polymorphic instance to use.
Use the pull-down menu to select an instance of this VI.
Place on the block diagram | Find on the Functions palette |
SI Data Samples (SISO Waveform)
data specifies the sample data source.
| |||||||||||||||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||||||||||||||
stimulus signal returns a sample stimulus waveform. | |||||||||||||||||||
response signal returns a sample response waveform. | |||||||||||||||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
SI Data Samples (SISO Array)
data specifies the sample data source.
| |||||||||||||||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||||||||||||||
stimulus signal returns a sample stimulus array. | |||||||||||||||||||
response signal returns a sample response array. | |||||||||||||||||||
sample rate returns the sample rate for the selected data source. | |||||||||||||||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
SI Data Samples (MIMO Waveform)
data specifies the sample data source.
| |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
stimulus signals returns sample stimulus waveforms. Each element of the waveform array is the waveform of one stimulus signal. | |||||||
response signals returns sample response waveforms. Each element of the waveform array is the waveform of one response signal. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
SI Data Samples (MIMO Array)
data specifies the sample data source.
| |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
stimulus signals returns sample stimulus arrays. Each row in the array is one stimulus signal. | |||||||
response signals returns sample response arrays. Each row in the array is one response signal. | |||||||
sample rate returns the sample rate for the selected data source. | |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|